Specifications |
Items | Specifications | |
Rated voltage | DC 12V | |
Operating temperature range | -22 ~ +176°F (-30°C ~ +80°C) | |
Rated load | Dimmer & passing switch | High : 0.2A (Relay load) Low : 0.2A (Relay load) Passing : 0.2A (Relay load) |
Lighting switch | Lighting : 0.2A (Relay load) | |
Turn signal switch | 6.6 ± 0.5A (Lamp load) | |
Wiper & mist switch | Low, High : 4.5A (Motor load) Intermittent : 0.22 ± 0.05A (Relay load) Lock : Max. 28A (Motor load) Washer : 4.0A (Motor load) | |
Front fog lamp switch | 0.2A (Relay load) | |
Rear wiper & washer | Wiper : 1.0A (Relay load) Washer : 4.0A (Motor load) |
Front Strut Assembly: Repair procedures
Replacement
1.
Remove the front wheel & tire.
Tightening torque :
88.3 ~ 107.9N.m (9.0 ~ 11.0kgf.m, 65.1 ~ 79.6lb-ft)
Be careful not to damage to the hub ...
Power Door Mirror Actuator: Repair procedures
Inspection
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front door delta cover.
(Refer to the BD group - "Front door")
3.
Disconnect the connector from the door mirror.
...