Inspection |
1. |
Turn the ignition switch OFF. |
2. |
Disconnect the RCV control solenoid valve connector. |
3. |
Measure resistance between the valve terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
2. |
Remove the RCV control solenoid valve after disconnect the connector (A), bolt (B) and RCV hose (C). |
Installation |
|
1. |
Installation is the reverse order of removal.
|
Power windows
The ignition switch must be in the ON position for power windows to operate.
Each door has a power window switch that controls the door's window. The driver
has a power window lock button which ...
Battery saver function
The purpose of this feature is to prevent the battery from being discharged
if the lights are left in the ON position. The system automatically turns off
the parking lights when the driver tu ...