Inspection |
1. |
There should be continuity between the No.11 in the A and
No.12 in the A terminals when power and ground are connected to the No.2
in the A and No.11 in the A terminals. |
2. |
There should be no continuity between the No.11 in the A and No.12 in the A terminals when power is disconnected. |
1. |
There should be continuity between the No.3 in the A and No.8
in the A terminals when power and ground are connected to the No.5 in
the A and No.6 in the A terminals. |
2. |
There should be no continuity between the No.3 in the A and No.8 in the A terminals when power is disconnected. |
1. |
There should be continuity between the No.17 in the A and
No.18 in the A terminals when power and ground are connected to the
No.16 in the A and No.17 in the A terminals. |
2. |
There should be no continuity between the No.17 in the A and No.18 in the A terminals when power is disconnected. |
Starter Relay: Repair procedures
Inspection
1.
Remove the fuse box cover.
2.
Remove the starter relay (A).
3.
Using an ohmmeter, check that there is continuity between each terminal.
TerminalContinuity30 - 87NO85 - 86Y ...
High Pressure Fuel Pump: Repair procedures
Removal
In case of removing the high pressure fuel pump, high
pressure fuel pipe, delivery pipe, and injector, there may be injury
caused by leakage of the high pre ...