Inspection |
1. |
Ignition "OFF” |
2. |
Disconnect the connector of mode control actuator. |
3. |
Verify that the mode control actuator operates to the defrost
mode when connecting 12V to the terminal 3and grounding terminal 4. |
4. |
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
|
5. |
Check the voltage between terminals 5 and 6.
It will feedback current position of actuator to controls. |
6. |
If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation. |
7. |
If the problem is corrected, replace the mode control actuator. |
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the crash pad left side cover (A). |
3. |
Remove the left extension cover(A). |
4. |
Remove the crash pad lower cover (A). |
5. |
Disconnect the diagnosis connector (A). |
6. |
Remove the reinforcing panel (A). |
7. |
Remove the left shower duct (A). |
8. |
Remove the BCM.
(Refer to BE group - "BCM") |
9. |
Disconnect the mode control actuator connector (A). |
10. |
Loosen the mounting screw and then remove the mode control actuator (B). |
11. |
Installation is the reverse order of removal. |
Power Mosfet: Repair procedures
Inspection
1.
Ignition "ON"
2.
Manually operate the control switch and measure the voltage of blower motor.
3.
Select the control switch to raise voltage until high speed.
Specification
...
Evaporator Temperature Sensor: Description and Operation
Description
The evaporator temperature sensor will detect the evaporator
core temperature and interrupt compressor relay power in order to
prevent evaporator freezing by excessive cooling ...