Inspection |
1. |
There should be continuity between the No.11 in the A and
No.12 in the A terminals when power and ground are connected to the No.2
in the A and No.11 in the A terminals. |
2. |
There should be no continuity between the No.11 in the A and No.12 in the A terminals when power is disconnected. |
1. |
There should be continuity between the No.3 in the A and No.8
in the A terminals when power and ground are connected to the No.5 in
the A and No.6 in the A terminals. |
2. |
There should be no continuity between the No.3 in the A and No.8 in the A terminals when power is disconnected. |
1. |
There should be continuity between the No.17 in the A and
No.18 in the A terminals when power and ground are connected to the
No.16 in the A and No.17 in the A terminals. |
2. |
There should be no continuity between the No.17 in the A and No.18 in the A terminals when power is disconnected. |
Voice Recognition
When using the voice recognition feature, only commands listed within the
user's manual are supported.
Be aware that during the operation of the voice recognition system, pressing
any k ...
ICM (Integrated Circuit Module) Relay Box: Description and Operation
Description
The ICM relay (A) is united with rear wiper relay, and DBC relay which installed inside the lower crash pad. ...