Kia Sportage: Evaporator Temperature Sensor: Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Kia Sportage SL Service & Repair ManualKia Sportage: Evaporator Temperature Sensor: Repair procedures

Third generation SL (2010–2016) / Kia Sportage SL Service & Repair Manual / Heating,Ventilation, Air Conditioning / Air Conditioning System / Evaporator Temperature Sensor: Repair procedures

Inspection
1.
Ignition "OFF".
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification
Evaporator core
temperature
[°C(°F)]
Resistance[K?]
Voltage[V]
-10(14)
17.93
3.22 ± 0.5
-5(23)
14.22
2.94 ± 0.5
0(32)
11.36
2.67 ± 0.5
5(41)
9.14
2.39 ± 0.5
10(50)
7.40
2.13 ± 0.5
15(59)
6.02
1.88 ± 0.5
20(68)
4.94
1.66 ± 0.5
25(77)
4.066
1.45 ± 0.5
30(86)
3.369
1.26 ± 0.5
35(95)
2.85
1.1 ± 0.5
40(104)
2.348
0.95 ± 0.5
45(113)
1.975
0.83 ± 0.5
50(122)
1.668
0.72 ± 0.5

Replacement
1.
Remove the console extension cover (A).

2.
Remove the evaporator temperature sensor (A), by pulling it after rotating 90° in a clockwise direction.

3.
Installation is the reverse order of removal.
Evaporator Temperature Sensor: Description and Operation
Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator freezing by excessive cooling ...

Photo Sensor: Description and Operation
Description 1. The photo sensor is located at the right of defrost nozzle. 2. The photo sensor contains a photovoltaic (sensitive to sunlight) diode. The solar radiation received by its lig ...

Other Information:

Audio Remote Control: Repair procedures
Inspection 1. Check for resistance between No.6 and No.7 terminals in each switch position. [Audio System] SwitchConnectorterminalResistance(±5%)Volume down6 - 76.81 k?Volume up6 - 74.61 k?Mut ...

Specifications
Specification ItemDescriptionPower source3VOperating temperature-20°C ~ +60°CRF ModulationFSKRF frequency433.92MHzBattery1EA (CR2032)     An inappropriately disposed bat ...

Categories