Oil Specification |
1. |
The HFC-134a system requires synthetic (PAG) compressor oil
whereas the R-12 system requires mineral compressor oil. The two oils
must never be mixed. |
2. |
Compressor (PAG) oil varies according to compressor model. Be sure to use oil specified for the model of compressor. |
1. |
The oil should be free from moisture, dust, metal powder, etc. |
2. |
Do not mix with other oil. |
3. |
The water content in the oil increases when exposed to the
air. After use, seal oil from air immediately. (HFC-134a Compressor Oil
absorbs moisture very easily.) |
4. |
The compressor oil must be stored in steel containers, not in plastic containers. |
Oil total volume in system
PAG OIL : 120 ± 10 cc |
1. |
Open all the doors and the engine hood. |
2. |
Start the engine and air conditioning switch to "ON" and set the blower motor control knob at its highest position. |
3. |
Run the compressor for more than 20 minutes between 800 and 1,000 rpm in order to operate the system. |
4. |
Stop the engine. |
Component parts to be installed | Amount of Oil |
Evaporator | 50 cc (1.70 fl.oz) |
Condenser | 30 cc (1.02 fl.oz) |
Receiver/dryer | 30 cc (1.02 fl.oz) |
Refrigerant line (One piece) | 10 cc (0.34 fl.oz) |
Even if no oil is drained from the removed compressor, don’t drain more than 50cc from new compressor. |
CVVT Oil Temperature Sensor (OTS): Description and Operation
Description
Continuous Variable Valve Timing (CVVT) system advances or
retards the valve timing of the intake and exhaust valve in accordance
with the ECM control signal which is calculated by ...
Starter: Schematic Diagrams
Circuit Diagram
...