Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A). |
3. |
Remove the air cleaner assembly.
|
4. |
Disconnect the solenoid valve connector (A). |
5. |
Measure resistance between sensor signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to "Valve Body" in Hydraulic System of this group) |
Canister Close Valve (CCV): Schematic Diagrams
Circuit Diagram
...
Special Service Tools
Special Service Tools
Tool (Number and name)IllustrationUseCrankshaft front oil seal installer(09214-3K000)(09231-H1100)Installation of the front oil sealA : 09214-3K000 (installer)B : 09231-H110 ...