Torque converter control solenoid valve (T/CON_VFS) is
attached to the valve body. This variable force solenoid valve directly
controls the hydraulic pressure inside the torque converter.
Inspection
1.
Check signal waveform of Input & output speed sensor using the GDS.
Specification: Refer to "Signal Wave Form" section.
Removal
1.
Remove the valve body assembly.
(R ...
Specifications
Direct control VFS[T/CON]
? Control type : Normal low type
Control Pressure kpa (kgf/cm?, psi)9.81 ~ 500.14(0.1 ~ 5.1,1.42 ~ 72.54)Current value(mA)50 ~ 850 Internal resist ...
Other Information:
Canister Close Valve (CCV): Description and Operation
Description
Canister Close Valve (CCV) is installed on the canister
ventilation line. It seals evaporative emission control system by
shutting the canister from the atmosphere when leakage dete ...
Canister Close Valve (CCV): Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the CCV connector.
3.
Measure resistance between the CCV terminal 1 and 2.
4.
Check that the resistance is within the specific ...