Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake
manifold. It is a solenoid valve and is open when the ECM grounds the
valve control line. When the passage is open (PCSV ON), fuel vapor
stored in the canister is transferred to the intake manifold.
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance between the injector terminals 1 and 2.
4.
Check that the resistance is within t ...
Ventilation
1.Set the mode to the position.
2.Set the air intake control to the outside (fresh) air position.
3.Set the temperature control to the desired position.
4.Set the fan speed control to the desired ...
Non-operational conditions of Back up warning system
The Back up warning system may not operate properly when:
1.Moisture is frozen to the sensor. (It will operate normally when the moisture
has been cleared.)
2.The sensor is covered with foreign ma ...