Inspection |
1. |
With the washer motor connected to the reservoir tank, fill the reservoir tank with water.
|
2. |
Remove the front bumper cover.
(Refer to the BD group - "Front bumper") |
3. |
Connect positive (+) and negative (-) battery cables to
terminals 2 and 1 respectively to see that the washer motor runs and
water is pumped. |
4. |
Check that the motor operates normally.
Replace the motor if it operates abnormally.
|
Line Pressure Control Solenoid Valve: Description and Operation
Description
line pressure control solenoid valve is attached to the valve
body. This variable force solenoid valve directly controls the
hydraulic pressure inside the line pressure. ...
Parking brake
Checking the parking brake
Type A
Check whether the stroke is within specification when the parking brake pedal
is depressed with 20 kg (44 lb, 196 N) of force. Also, the parking brake alone sho ...