Specifications |
Description | Specification | |
Ultrasonic sensor | Detecting range | 9.8~47.2 in (250 ~ 1,200 mm) |
Operating voltage | DC 8~10 V | |
Rated current | MAX. 20 mA | |
Operating temperature | -22°F~+176°F(-30°C ~ +80°C) | |
Preservation temperature | -40°F~+185°F(-40°C ~ +85°C) | |
Frequency | 48 ± 5 KHZ | |
Number of sensors | 4 EA(Right, Center-right, Center-left, Left) | |
Piezo buzzer | Rated voltage | DC 12 V |
Operating voltage | DC 9~16 V | |
Operating temperature | -22°F~+176°F(-30°C ~ +80°C) | |
Preservation temperature | -40°F~+185°F(-40°C ~ +85°C) | |
Rated current | MAX. 60 mA | |
Sound, tone | Oscillation frequency : 2.0 ± 0.5 KHz | |
Sound level : MIN 65 dB (DC 13 V/m) |
Front Wiper Motor: Repair procedures
Removal
1.
Remove the windshield wiper arm and blade after removing a nut (B) and wiper cap (A).
2.
Remove the windshield wiper arm and blade (A).
3.
If necessary, release the wiper blade ...
Interior care
Interior general precautions
Prevent chemicals such as perfume, cosmetic oil, sun cream, hand cleaner, and
air freshener from contacting the interior parts because they may cause damage or
discol ...