Purge Control Solenoid Valve (PCSV) is installed on the surge
tank and controls the passage between the canister and the intake
manifold. It is a solenoid valve and is open when the ECM grounds the
valve control line. When the passage is open (PCSV ON), fuel vapor
stored in the canister is transferred to the intake manifold.
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance between the injector terminals 1 and 2.
4.
Check that the resistance is within t ...
26 Brake Control Solenoid Valve(26/B_VFS): Specifications
Specifications
Direct control VFS[26/B]
? Control type : Normal low type
Control Pressure kpa (kgf/cm?, psi)9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54)Current value(mA)50 ~ 850 Internal resist ...
4WD ECU: Description and Operation
Description
4WD ECU processes signals from various sensors and determines
the current road and driving conditions. The ECU then utilizes this
information to implement precision control over the ...