Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A). |
3. |
Remove the air cleaner assembly.
|
4. |
Disconnect the solenoid valve connector (A). |
5. |
Measure resistance between sensor signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to "Valve Body" in Hydraulic System of this group) |
CVVT Oil Temperature Sensor (OTS): Schematic Diagrams
Circuit Diagram
...
Telemetics Unit (TMU): Components and Components Location
Component
Connector Pin Specification
No.Pin NameTypeFromToDescription (Wiring Spec.)1GNDDC GroundTMUBatteryConnected to battery ground2GNDDC GroundTMUBatteryConnected to battery ground3-----4-- ...