Inspection |
1. |
Turn the ignition switch OFF. |
2. |
Disconnect the OCV connector. |
3. |
Measure resistance between the OCV terminals 1 and 2. |
4. |
Check that the resistance is within the specification.
|
Removal |
[Bank 1 / Intake] |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
2. |
Remove the OTS (A). |
3. |
Disconnect the CVVT oil control valve connector (B). |
4. |
Remove the installation bolt (C), and then remove the valve from the engine. |
[Bank 1 / Exhaust] |
1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
2. |
Disconnect the CVVT oil control valve connector (A). |
3. |
Remove the installation bolt (B), and then remove the valve from the engine. |
Installation |
|
|
1. |
Installation is reverse of removal.
|
Description and Operation
Description
Automatic transaxle system relies on various measurement data
to determine the current control status and extrapolate the necessary
compensation values. These values are used to con ...
Output Speed Sensor: Specifications
Specifications
? Type: Hall effect sensor
Operation condition (°C)°F(-40~150) -40~302Air gap (mm)in.(0.25~0.70) 0.0098~0.0276Output voltage (V)High1.18 ~ 1.68Low0.59 ~ 0.84
...