Specifications |
Item | Requirement | Remark |
Rated voltage | DC 12V | |
Operating voltage range | DC 9 ~ 16V | Shall activate normally in these range |
Operating temperature range | -30°C ~ +80°C | Shall conserve normally in these range. |
Storage temperature range | -40°C ~ +85°C | |
Max humidity in use | 95% | |
High voltage resistance | 24V/1min, 18V/1hour | After overvoltage is the Normal behavior |
Insulation resistance | 100M? or more (measured with 500V MEGGER) | Specify as well as parts that insulation like PCB, moisture-proof COATING is required. |
Quiescent current | KEYLESS spec : 6mA or less SMK spec : 5.5mA or less NON-KEYLESS : 4mA or less | Measure when the state, all output loads are OFF and there are no Input SW(including TX operation) changes, continues 2sec. |
Voltage drop | 1.2V or less | but, Terminal B9, B20, C1, C2, C3, C13, C14, C15, C16 is 2.0V or less. |
Canister: Repair procedures
Removal
1.
Remove the fuel tank. (Refer to "Fuel tank" in FL group.)
2.
Disconnect the vapor tube quick-connector (B) and the ventilation hose (A).
3.
Remove the canister in the direction ...
ETC (Electronic Throttle Control) System: Schematic Diagrams
Circuit Diagram
...