Description |
1. |
The ambient temperature sensor is located at the front of the
condenser and detects ambient air temperature. It is a negative type
thermistor; resistance will increase with lower temperature, and
decrease with higher temperatures. |
2. |
The sensor output will be used for discharge temperature
control, temperature regulation door control, blower motor level
control, mix mode control and in-car humidity control.
|
Condenser: Repair procedures
Inspection
1.
Check the condenser fins for clogging and damage. If clogged,
clean them with water, and blow them with compressed air. If bent,
gently bend them using a screwdriver or pliers.
...
Side Impact Sensor (SIS): Description and Operation
Description
Side Impact Sensor (SIS) system consists of two P-SIS which
are installed at each center of the front door module (LH and RH) and
two SIS which are installed at each center pillar n ...