Specifications |
Control Pressure kpa (kgf/cm?, psi) | 9.81 ~ 500.14 (0.1 ~ 5.1,1.42 ~ 72.54) |
Current value(mA) | 50 ~ 850 |
Internal resistance(?) | 5.1 |
Panoramaroof: Repair procedures
Replacement
Movable Glass Replacement
1.
Remove the roof rack and roof moulding.
(Refer to the BD group - "Body Side Mouldings")
2.
Open the movable glass.
3.
Loosen the movable glass (A ...
Input Speed Sensor: Repair procedures
Inspection
1.
Check signal waveform of Input & output speed sensor using the GDS.
Specification: Refer to "Signal Wave Form" section.
Removal
1.
Remove the valve body assembly.
(R ...