1.Set the fan speed to the highest position.
2.Set the temperature to the extreme hot (HI) position.
3.Press the defroster button ().
4.The outside (fresh) air position will be selected automatically and the air conditioning will turn on according to the detected ambient temperature.
Pressure Sensor: Repair procedures
Inspection
If you have trouble code related to the pressure sensor
(P1825, P1826, P1827, P1828), check pressure sensor according to the
inspection process.
Pre ...
Hands Free Switch: Repair procedures
Inspection
1.
Check the handsfree remote control switch for resistance between No.3 and No.4 terminals in each switch position.
[Call + Hang Up]
SwitchConnector terminalResistance (±5%) Output ...