Self Diagnosis |
1. |
Self-diagnosis process |
2. |
How to read self-diagnostic code
After the display panel flickers three times every 0.5
second, the corresponding fault code flickers on the setup temperature
display panel every 0.5 second and will show two figures. Codes are
displayed in numerical format
Fault Code
|
3. |
Fault code display
|
4. |
If fault codes are displayed during the check, Inspect specific malfunctions causes by fault codes. |
5. |
Fail safe
|
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Using the screwdriver, remove the cluster facia panel (A). |
3. |
Using the screwdriver, remove the crash pad garnish (A). |
4. |
Using the screwdriver, remove the center facia panel (A). |
5. |
Disconnect the center facia connectors (A). |
6. |
Loosen the control panel mounting screws and then remove the control panel (A). |
7. |
Disconnect the connectors and then remove the control panel (B). |
8. |
Installation is the reverse order of removal. |
Temperature Control Actuator: Description and Operation
Description
1.
Heater unit includes mode control actuator and temperature control actuator.
2.
Temperature control actuator is located at the heater unit.
It regulates the temperature by the ...
Automatic heating and air conditioning
1.Press the AUTO button.
The modes, fan speeds, air intake and air-conditioning will be controlled automatically
according to the temperature setting.